(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth

Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
(UN2000A) Transport Remote Touchscreen ETCO2 Patient Monitor with Bluetooth

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation



Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm


SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm


NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 


Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC


EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm


Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH

Storage Operation/relative humidity:-20~60ºC/10~90%RH



(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth
(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth


Payment

(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth




 
(UN2000A) Transport Remote Touchscreen ETCO2 Patient Monitor with Bluetooth

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation



Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm


SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm


NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 


Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC


EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm


Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH

Storage Operation/relative humidity:-20~60ºC/10~90%RH



(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth
(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth


Payment

(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Transport Remote Touchscreen Etco2 Patient Monitor with Bluetooth




 

Tattoo Machine Parts is for people make tattoo machines.

Professional manufacturer of Tattoo Machine Parts in china, Specialize In Manufacturing Wholesale Tattoo Machine Coil, Tattoo Machine Spring, Tattoo Machine Screw, etc

Tattoo Machine Coil, Tattoo Machine Spring, Tattoo Machine Screw | China Tattoo Machine Parts Manufacturers

Tattoo Machine Spring

Tattoo Machine Spring, Tattoo Spring, Tattoo Contact Spring

Redtop Tattoo Supply Co., Limited , http://www.redtop-tattoo.com